Research on the Non-crossing Layout Mode of OCS in Turnout 18# Zone of Passenger Dedicated Line |
LUO Jian, HAN Ling-Qing, LIN De-fu |
The Third Railway Survey and Design Institute Group Corporation, Tianjin 300251,China |
|
|
Abstract Research purposes: In order to match the construction of Shijiazhung-Taiyuan Passenger Dedicated Line, the researches are done on the non-layout mode of OCS in turnout 18" zone based on introducing, digesting and absorbing the foreign advanced technologies for the purpose of providing the technical support to construction of Shijiazhuang-Taiyuan Passenger Dedicated Line.
Research conclusions: Simple non-crossing mode is easy to arrange and fix because the system has no crossing between OCS' on main line and sideline. In this mode, the guiding OCS is between main line and sideline and contacts the pantograph all along in turnout center area, so the pantograph can transit from sideline to main line or from main to sideline, the impulsion to OCS on main line can be reduced and there is no off-normal abrasion in guiding OCS. The non-crossing with guiding catenary mode is adaptive to high-speed railway with feature of better performance of current collection between pantograph and catenary. It is used in China for the first time and should be adopted widely in passenger dedicated line.
|
Received: 23 April 2008
|
|
|
|
|
[1] 于万聚.高速电气化铁路接触网[M].成都:西南交通大 学出版社,2002.
[2] 基布岭[德],等.电气化铁道接触网[M].中铁电气化 局集团有限公司,译.北京:中国电力出版社,2003.
[3] 吉鹏霄.接触网[M].北京:化学工业出版社,2006.
|
|
|
|