Research on Lightning Protection Effect of Lighting Arrester on Catenary |
ZHANG Xue—yuan |
Chegndu University of Information Technology,Chengdu,Sichuan 610225,China |
|
|
Abstract Research purposes: The over—voltage of lighting seriously threats the reliability of power supply to the electrified railway.To install the lighting arrester on the catenary is one of ways to reduce lighting disaster,but now there is no theory on analysis of the lighting protection effect of lighting arrester on catenary.In this paper,based on the insulated strength of insulator of catenary and possibility distribution of lighting current,the analysis is made for the tripping situation caused by lighting when there is and there is no arrester on the catenary.
Research conclusions: The research shows as the external insulation level of the catenary of electrified railway is low,the insulator on support post is easy to flash over continuously under the over voltage of lighting.The attention should be paid to this when making analysis of the lighting—resistance capacity of the catenary and taking measures for lighting protection,otherwise,the big error will be brought out.The arrester is not suitable for the distributed lighting protection way in broad area,but it can obtain good effect for the lighting concentrated area with installation of it coneentratively.
|
Received: 16 December 2009
|
|
|
|
|
[1] 于增.接触网防雷技术研究[J].铁道工程学报, 2002 (1): 89 -94.
Yu Zeng. Study on Lightning Protection of Catenary [J], Journal of Railway Engineering Sosiety, 2002(1): 89 -94.
[2] Ken Uehara GO. Investigation of lightning damages on distribution lines [ J ]. IEEE Transactions on Power Application and Systmes, 1968(4): 1018 -1025.
[3] Philip P. Barker, Ramon T.Mancao, David J.Kvaltine EA. Characteristics of lightning surges measured at metal oxide distribution arresters [ J ]. IEEE Transactions on Power Delivery, 1993(3): 301 -310.
[4] McDaniel J. Line arrester application field study[C ] // Transmission and Distribution Conference and Exposition, 2001: 1025 -1029.
[5] Short T. A., Ammon R.H.. Monitoring results of the effectiveness of the surge arrester spacing on distribution line pretection [J]. IEEE Trans. Power Delivery, 1999 (14): 1142 -1150.
[6] McDerrott T. E., Short T. A., Anderson J. G.. Lightning protection of distribution Line [J ]. IEEE Trans. Power Delivery. 1994(9): 138 -152.
[7] Zoro R, Zoro R, Mefiardhi R, eta.l Observation on improved 20 kV 's overhead distribution lines against lightning[C ] //Properties and Applications of Dielectric Materials, 2006. 8th International Conference on, 2006: 979 -983.
[8] Sadovic S., Joulie R., Tartier S., eta.l Use of line surge arresters for the improvement of the lightning performance of 63 kV and 90 kV shielded and unshielded transmission lines[J]. IEEE Trans. Power Delivery, 1997(3): 1232 -1240.
[9] Luiz Cera Zanetta Jr.. Evaluation of line surge arrester failure rate for multipulse lightning stresses[J]. IEEE Trans. Power Delivery, 2003(3): 796 -801.
[10]Tarchini J. A., G im enez W.. Line surge arrester selection to improve lightning performance of transmission lines n [C ]. Power Tech Conference Proceedings, 2003 IEEE Bologna, 2003(2): 23 -26.
[11]W ahab Y. A., Abidin Z. Z., Sadovic S.. Line surge arrester application on the quadruple circuit transmission line n [C ]. Power Tech Conference Proceedings, 2003 IEEE Bologna, 2003(3): 23 -26.
|
|
|
|