Discharging Current and Monitoring of Mental Underground Pipeline Around Metro |
SUN Xiang-kun |
China Railway Siyuan Survey and Design Group Co. Ltd, Wuhan, Hubei 430063 ,China |
|
|
Abstract Research purposes: With the rapid development of the metro in China in recent years, the metro track passes the city populated area,with crossing the mental natural gas pipe,the mental petroleum pipe and the mental chemical pipe. These mental pipes will be corrosive because of the stray current produced by the AC power supply system of the metro. This paper discusses and analyzes the monitoring of the mental pipelines around the metro and the protection of discharging the current cathodically.
Research conclusions: Now the problems caused by the pipeline crossing and paralleling with the metro track become more and more, so the pipeline operators should cooperate with the metro operator. (1) The metro designer and operator of the metro should control the total volume of the stray current,monitor the internal system and discharge the current to make the stray current in the certain range with on impact on the external system. (2) The pipeline operators should insulate and cathodically protect the pipeline. In the area where the pipeline crosses or parallels with the metro track, the monitoring spot should be added, the corrosion-proof coating should be thickened and the anodic discharge current should not be conducted.
|
Received: 14 September 2012
|
|
|
|
|
[1] 翁永基,李英义,韩昌柴,等.埋地管道直流干扰腐蚀研究-I检测指标和评价体系[J]. 腐蚀科学与防护技术,2010(1): 1-3. Weng Yongji,Li Yingyi,Han Changchai,etc. Study on Buried Pipeline DC Interference Corrosion-I Detect Indicators and Evaluation System [J]. Corrosion Science and Protection Technology, 2010(1): 1-3.
[2] 深圳燃气集团股份有限公司.深圳燃气管道杂散电流预备性测试工作报告[R].深圳:深圳燃气集团股份有限公司,2008. Shenzhen Gas Corporation Ltd. Shenzhen Gas Pipeline Stray Current Prepare Test Report [R]. Shenzhen: Shenzhen Gas Corporation Ltd,2008.
[3] Thomas J B,Alan D Z. Stray Current Corrosion in Electrified Rail Systems: ITl Projects [R]. USA: Northwestern University of America,1998.
[4] 卢木,王濮信,卢金勇.混凝土中钢筋锈蚀研究现状[J]. 混凝土,2000(12): 37-41. Lu Mu,Wang Puxin,Lu Jinyong. State-of-art in the Study of the Corrosion of Reinforcing Steel in Concrete [J]. Concrete, 2000(12): 37-41.
[5] SY/T 0017—2006,埋地钢质管道直流排流保护技术标准规定[S]. SY/T 0017—2006,Buried Pipeline DC Discharge Protection Technical Standards [S].
[6] SY/T 008—95,钢质管道及储罐腐蚀与防护调查标准[S]. SY/T 008—95,Corrosion and Protection of Steel Pipeline and Tank Survey Standards [S].
[7] 胡先茂.城市轨道交通对埋地管线影响范围的分析[J]. 现代城市轨道交通,2011(3): 74-76. Hu Xianmao. Analysis on Influence Scope of Urban Rail Transit on Buried Pipeline[J]. Modern Urban Transit, 2011(3): 74-76.
[8] 胡士信.阴极保护工程手册[M].北京:化学工业出版社,1999. Hu Shixin. Handbook of Cathodic Protection Engineering [M]. Beijing: Chemical Industry Press,1999.
|
|
|
|