Application Research on Percussion Hole Double Cage Pouring Pile in the Complex Formation |
CHANG Ju-you,WANG Yu,YAN Yan,QIAO Song,LIU Zu-fu |
China Railway Eryuan Engineering Group Co.Ltd,Chengdu,Sichuan 61003 1,China |
|
|
Abstract Research purposes:Reflected wave method is used to investigate the integrity of the single cage pouting pile, validation found out there are serious expanding diameter and exposed reinforcement in the Complex Formation.both waste of concrete and the impact of the integrity of pile.Therefore should be studied,find out the reason,improved the construction method,not only can save concrete,but also ensure the concrete quality of pile body integrity.
Research conclusions:(1)Impact hole single cage pile expanding diameter mainly due to the impact force to impact into the hole,put flow sand in underground water level,gravel,silt,and soft plastic clay layer contact the bedrock,as well as the cavities within the filling fabric impact into the hole,respectively by the mud return hole with a hole,which is larger than the diameter of pile formed around the construction of underground space,underground space concrete large expanding diameter,the corresponding expanding appear above the necking and exposed reinforcement; (2)Impact hole single cage pile can be made in hard plastic silty clay layer that have not groundwater;(3)Percussion hole double cage pouting pile construction should be used in order to prevention of expanding diameter and expose reinforcement of the concrete and ensure the concrete quality of pile body integrity in the sand,gravel,silt flow layer that have groundwater;(4)Percussion hole double cage pouring pile should be applied and generalized in the field of percussion hole pouting pile.
|
Received: 18 May 2013
|
|
|
|
|
[1]JGJ 106-2003,建筑基桩检测技术规范[S].
JGJ 106-2003,Technical Code for Testing of Building Foundation Piles[S].
[2]TB 10218-2008,铁路基桩检测技术规程[S].
TB 10218-2008,Technical Code for Testing of Foundation Piles of Railway Engineering[S].
[3]JGJ79-2002,建筑地基处理技术规范[S].
JGJ 79-2002.Technical Code for Ground Treatment of Buildings[S].
[4] GB 50021-2001,岩土工程勘察规范[S].
GB 50021-2001,Code for Investigation of Geotechnical Engineering[S].
[5]TB 10013-2010,铁路工程物理勘探规程[S].
TB 10013-2010,Code for Geophysical Prospecting of Railway Engineering[S].
[6]TB 10102-2004,铁路工程土工试验规程[S].
TB 10102-2004,Code for Soil Test of Railway Engineering[S].
[7] GB/T 50123-1999,土工试验方法标准[S].
GB/T 50123-1999,Standard for Soil Test Method [S].
[8] 常聚友,刘志军,周其祥.路基端承灌注桩完整性及承载力研究[J].铁道工程学报,2008(2):35-39.
Chang Juyou,Liu Zhijun,Zhou Qixiang.Research on Completeness and Bearing Capacity of End Bearing Cast-in-place Pile for Subgrade[J].Journai of Railway Engineering Society,2008(2):35-39.
|
|
|
|