Abstract:Research purposes: As using the complete analysis method for beam on elastic foundation calculate the internal force as well as the displacement of the deep foundation ditch enclosure structure,the internal bracings was applied in advanced and the calculation condition was inconsistent with the actual of the construction,a method that considered the erection time of the inner bracings was proposed in this paper in order to improve the calculation accuracy.
Research conclusions: (1)As the bar-system FEM complete analysis method for beam on elastic foundation was adopted to calculate the internal force and the displacement of the foundation ditch enclosure structure,the inner bracing was defined as compression-only bar unit with initial gap,and the width of the initial gap was equal to the lateral displacement of fender piles(or enclosure wall) on the point which the inner bracings were applied at the erection time. With that the erection time of the bracings were considered in the model,which makes the internal force and displacement calculations of the enclosure structure accord the actual better.(2)Without considering the erection time of the bracings while using the complete analysis method for beam on elastic foundation,the calculated values of the lateral displacements and moments of the fender piles(or enclosure wall ) were smaller , that was not safety in practice. ( 3 ) Research findings of this paper can provide reference for the design and construction of foundation ditch enclosure structure.
刘成禹,徐代宏. 考虑支撑架设时机的基坑围护结构计算方法[J]. 铁道工程学报, 2013, 30(11): 13-17.
LIU Cheng-yu 1,XU Dai-hong 2. Calculation Method of Foundation Ditch Enclosure Structure Considered the Erection Time of Bracings. 铁道工程学报, 2013, 30(11): 13-17.
Huo Runke, Yan Mingyuan, Song Zhanping. The Monitoring and Numerical Anaysis of Deep Foundation in Subway Station [ J ].Journal of Railway Engineering Society, 2011 (5):81-85.
Huang Shengping, Han Minghua. Study on Test for Supporting System for Deep Foundation Pit of Metro Transfer Station[J].Journal of Railway Engineering Society, 2012(5):58-62.
Ren Jianxi, Gao Tao. Research on the Deformation Law of Deep Excavation Supporting Structure in Metro Interchange Station by FLAC Simulation[J].Journal of Railway Engineering Society , 2008 (9 ):80-83.
Gao Lixin, Wang Qiang, Li Guojie. In-situ Monitoring of Deformation Laws of Deep Foundation Pit of Subway Station [ J ].Journal of Railway Engineering Society , 2011(11):112-116.
Zhang Qiangyong. Application of Bar System FEM for Beam on Elastic Foundation in Supporting Design for a Deep and Large Foundation Pit Engineering[J]. Journal of Building Structures , 2005 ( 3 ):114-117.
Yang Guanghua. Practical Calculation Method of Retaining Structures for Deep Excavations and Its Application [ J ].Rock and Soil Mechanics, 2004(12): 1885-1896.
[8]JGJ 120—99,建筑基坑支护技术规程[S].
JGJ 120—99,Technical Specification for Retaining and Protection of Building Foundation Excavations[S].