牵引变电所防雷加强措施的研究

陈兴强

铁道工程学报 ›› 2015, Vol. 32 ›› Issue (6) : 76-80.

PDF(431 KB)
PDF(431 KB)
铁道工程学报 ›› 2015, Vol. 32 ›› Issue (6) : 76-80.
电气化工程

牵引变电所防雷加强措施的研究

  • 陈兴强
作者信息 +

Research on the Strengthening Measures of Lightning Protection for the Traction Substation

  • CHEN Xing一qiang
Author information +
文章历史 +

摘要

研究目的:随着电气化铁路的发展,雷电一直是危害牵引变电所安全可靠运行的重要因素之一。近年来,牵引变电所雷击事故时有发生,为加强牵引变电所的防雷水平,针对某220 kV牵引变电所发生的雷击事故进行研究,该事故使牵引变电所设备烧损严重,具有一定的典型性。本研究旨在通过对雷电流幅值、雷击点过电压、建弧率、短路电流等的计算,分析事故发生的原因和过程,提出防雷加强措施,避免此类事故再次发生。
研究结论:(1)如果架空回流线架设过高,当雷击回流线时直击雷将通过电缆直接引人到变电所内,另外,供电线不设进线保护段,则可能烧毁避雷器;(2)供电线首端架设避雷线、加强接地及研究母线保护等措施,可以进一步提高牵引变电所的防雷水平;(3)该研究成果主要应用于牵引变电所的防雷方案优化和设计领域。

Abstract

Research purposes:With the development of the electrified railways,lightning is one of the important factors which endangering safe and reliable operation of the traction substation. The lightning accident of the traction substation was occurred from time to time. In order to improve the traction substation’s lightning protection level,it is studied according to the lightning accident of a 220 kV traction substation. It’s a typical accident and the equipments of the traction substation are damaged seriously. This study aims to analyze the cause and the process of this accident based on the calculation of the lightning current amplitude,lightning overvoltage,arcing rate,and the short circuit current,give the strengthening measures of lightning protection to avoid the similar accident.
Research conclusions:(1)The direct lightning stroke will be led into the substation when the lightning strikes the overhead return line if it’S lnstalled t00 high arid the arrester Wlll be destroyed if the Overhead feeder hne lsn’t installed incoming protection line. (2)Some proposals can improve the substation’s lightning protection lever, such as installing the incoming lightning protection line of the feeder, strengthening the grounding line,researching the bus一bar protection relay,and so on.(3)The research results are mainly used for optimization program and design fields on the traction substation lightning protection.

关键词

电气化铁路 / 牵引变电所 / 防雷

Key words

electrified railway / traction substation / lightning protection

引用本文

导出引用
陈兴强. 牵引变电所防雷加强措施的研究[J]. 铁道工程学报, 2015, 32(6): 76-80
CHEN Xing一qiang. Research on the Strengthening Measures of Lightning Protection for the Traction Substation[J]. Journal of Railway Engineering Society, 2015, 32(6): 76-80

参考文献

[1]周泽存.高电压技术[M].北京:水利电力出版社,1994. Zhou Zecun. High Voltage Technology[M].Beijing: China Water Power Press, 1994.
[2]西北电力设计院.电力工程电气设计手册(1)[M].北 京:中国电力出版社,2008.
Northwest Electric Power Design Institute. Electric Power Engineering Electricity Design Manual (1)[M]. Beijing:China Electric Power Press, 2008.
[3]解广润.电力系统过电压[M].北京:水利电力出版社, 1985.
Xie Guangrun. Electrical Power System Overvoltage [M].Beijing:China Water Power Press, 1985.
[4]李景禄,胡毅,刘春生.实用电力接地技术[M].北京:中 国电力出版社,2002.
Li Jinglu, Hu Yi, Liu Chunsheng. Practice Electric Power Grounding Technology[M]. Beijing:China Electric Power Press, 2002.
[5]李汉卿.雷击变电所地网暂态过电压规律分析[J].铁 道工程学报,2014(9):93-96.
Li Hanqing. Regularity Analysis on Transient Over- voltage of Grounding Grid by Lightning Strokes in Substations[J].Journal of Railway Engineering Society, 2014(9) :93-96.
[6]董振亚.电力系统的过电压保护[M].北京:中国电力出 版社,1997.
Dong Zhenya. Overvoltage Protection of the Electrical Power System[M].Beijing:China Electric Power Press, 1997.
[ 7 ] GB/T 50065-2011,交流电气装置的接地设计规范[S].
GB/T 50065-2011,Code for Design of AC Electrical Installations Earthing [ S ].
[8]吴广宁,曹晓斌,李瑞芳.轨道交通供电系统的防雷与接 地[M].北京:科学出版社,2011.
Wu Guangning, Cao Xiaobin, Li Ruifang. Lightning Protection and Grounding Technology of Railway Traffic Power System[M].Beijing:Science Press, 2011.
[ 9 ] GB 11032-2010,交流无间隙氧化物避雷器[S].
GB 11032-2010,Metal-oxide Surge Arresters without Gaps for A. C. System [ S ].
[ 10 ] DL/T 620-1997,交流电气装置的过电压保护和绝缘配 合[S].
DL/T 620-1997,Overvoltage Protection and Insulation Coordination for AC Electrical Installations [ S ].