Time - frequency Analysis of Dynamic Responses for Super - tall Buildings under Typhoons |
GU Yuan-sheng,LI Chun-xiang,LI Jin-hua |
Shanghai University, Shanghai 200072, China |
|
|
Abstract Research purposes : With the height and ratio increasing,material being low-weight and high-strength, structure system being complex,super - tall building always suffer acute swing under typhoons. So it is extraordinary importance to choose design parameters,forecast structure response,reinforce data of modal parameters,verify design veracity that time-frequency analysis of dynamic responses for super - tall buildings under typhoons.
Research conclusions : By resorting to full-scale measurements of typhoon effects on a super-tall building,the dynamic characteristics of the super - tall building can be obtained with the measured data. Meanwhile,an evaluation may be carried out on the reliability of typhoon - induced responses. The time - frequency analysis methods of typhoon - induced responses of super -tall buildings mainly include the Fourier transform,wavelet transform,and Hilbert-Huang transform (HHT). This paper demonstrates 3 methods mentioned above in detail to summarize their advantages and disadvantages and to further prospect the trends of future researches in this domain.
|
Received: 17 November 2007
|
|
|
|
|
[1]Ii Q S, FuJ Y, Xiao Y Q, LiZN, Ni Z H, XieZN, Gu M. Wind tunnel and full - scale study of wind effects on China′s tallest building[J]. Engineering Structures,2006,28 (12); 1745 -1758.
[2]Kareem A K, Kijewski T. Time - frequency analysis of wind effects on structures[ J]. Journal of Wind Engineering and Industrial Aerodynamics, 2002,90( 12 -15) : 1435 —1452.
[3]Wu J R, Liu P F, Li Q S. Effects of amplitude - dependent damping and time constant on wind - induced responses of super tall building[ J]. Computers & Structures,2007,85 (15 -16): 1165 -1176.
[4]Li Q S, Wu J R. Time - frequency analysis of typhoon effects on a 79 - storey tall building [ J ]. Journal of Wind EngineeringandlndustrialAerodynamics,2007,95 ( 12) : 1648 -1666.
[5]Li Q S, Yang K, Zhang N, Wong C K, Jeary A P. Field measurements of amplitude - dependent damping in a 79 - storey tall building and its effects on the structural dynamic responses [ J ].Structural Design of Tall Buildings,2002,11 (2):129 -153.
[6]Li Q S, Xiao Y Q, Wong C K. Full-scale monitoring of ty-phoon effects on super tall buildings[ J]. Journal of Fluids and Structures, 2005,20(5) : 697 - 717.
[7]Li Q S, Xiao Y Q, Wong C K,Jeary A P. Field measure?ments of wind effects on the tallest building in Hong Kong [J]. The Structural Design of Tall and Special Buildings, 2003,12(l):67 -82.
[8]Li Q S, Xiao Y Q, Fu J Y, Li Z N. Full - scale measure?ments of wind effects on the Jin Mao building[ J]. Journal of Wind Engineering and Industrial Aerodynamics,2007,95 (6):445 - 466.
[9]Li Q S, Yang K E, Wong C K, Jeary A P. The effect of am-plitude -dependent damping on wind-induced vibrations of a super tall building[ J]. Journal of Wind Engineering and Industrial Aerodynamics, 2003 ,91(9) :1175 - 1198.
|
|
|
|