Over-voltage Analysis and Suppression in the Traction Network Double Neutral Section Electrical Sectioning Device |
QU Zlu-jian, LIU Yu-xin , ZHOU Min |
East China Jiaotong University,Nanchang, Jiangxi 330013 China |
|
|
Abstract Research purposes:In order to research over-voltage produced by electric locomotive power outage over split-phase which makes equipment insulation breakdown,chain-type equivalent circuit model of timing switch control is established. The new suppression method which suppress the over-voltage is proposed compared with the over -voltage produced by joint simulation model in the single and double neutral section of seven/eight span overlapping electrical sectioning device in electric locomotive-electrical sectioning-traction network.
Research conclusions:(1)The over-voltage of seven-span overlapping electrical sectioning device is consistent with the test results of literature,and the residual pressure co-simulation and the theoretical value are about 11 kV,which further prove the effectiveness of the simulation.(2)The maximum overvoltage decreases from 95. 57 kV in the single neutral section of the seven-span overlapping electrical sectioning device to 59. 28 kV in the bilateral neutral passive RC circuit of the eight-span overlapping electrical sectioning device,which suppressive effect is obvious. (3)Experimental results have the important reference value for anchor section joint electrical phase design.
|
Received: 15 July 2013
|
|
|
|
|
[1]刘明光.铁道电网过电压分析与防护-电网、暂态、防雷 与接地[M].北京:北京交通大学出版社,2009.
Liu Mingguang. Over-voltage Analysis and Protection of Railway Power Supply Network[M].Beijing : Beijing University Press, 2009. [2]赵小乐,张宪,李晓雷.浅谈接触网三断口八跨锚段关节式电分相技术[J].铁道建筑技术,2010(7):22-29.
Zhao Xiaole , Zhang Xian , Li Xiaolei. Preliminary Discussion on the Technology about Catenary on Three Fracture Overlapping Electrical Sectioning Device[J]. Railway Construction Technology , 2010 (7 ) : 22-29.
[3]隋延民.电气化铁道接触网关节式分相技术要点探讨 [J].中国铁路,2010(11):30-34.
Sui Yanmin. Key Problems of Electrified Railway Catenary Electric Split Phase Technology[J].Chinese Railways,2010(11):30-34.
[4]吴命利.电气化铁道牵引网的统-链式电路模型[J]. 中国电机工程学报,2010(28):52-58.
Wu Mingli. Uniform Chain Circuit Model for Traction Networks of Electric Railways[J].Proceedings of the CSEE,2010(28):52-58.
[5]杨培斌,张占胜,张金胜,等.牵引变电所倒闸操作引起谐振过电压原因及对策[J].铁道机车车辆,2006(26):68-70
Yang Peibin, Zhang Zhansheng, Zhang Jinsheng, etc. The Cause and Countermeasures of Resonance Overvoltage Produced by Traction Substation Switching Operation [ J ].Railway Locomotive&Car, 2006(26): 68-70.
[6]朱学辉,陈玉泉,张虎年,等.关节式电分相线索烧损原因及防范措施[J].电气化铁道,2007(4):32-35.
Zhu Xuehui,Chen Yuquan, Zhang Human, etc. Causes of Burn-out of Articulated Phase Breaker Cable and Its Prevention Measures[J].Electric Railway , 2007 ( 4 ) : 32-35.
[7]付强.接触网锚段关节式电分相[J].电气化铁道,2005 (2):30-32.
Fu Qiang. Overlapping Electrical Sectioning Device of OCS[J].Electric Railway , 2005 ( 2 ) : 30-32.
[8]李娜.电力机车系统电磁暂态过程研究[D].北京交通大学博士学位论文,2010.
LI Na. Research on Electromagnetic Transient Process of Electric Locomotive System[D].Doctoral Dissertation of Beqing Jiaotong University, 2010.
[9]曲昌军,邓云川.牵引变电所过电压问题研究[J].铁道工程学报,2007(8):81-84.
Qu Changjun, Deng Yunchuan. The over-voltage Problem Research on Traction Substation [ J ].Journal of Railway Engineering Society , 2007 ( 8 ) :81-84.
|
|
|
|