Abstract:Research purposes: Through the comparison and analysis of the calculation example,the study is done on the internal force and displacement characteristics when installing arched conversion layer at different heights to the frame structure.
Research conclusions: Compared with the structure of no conversion layer,the intemal force of the structure member above the conversion layer changes a little while the internal force of the every flayer below the conversion layer increase much.For the structures of conversion layers at different heights。the internal force of the structure member below the conversion layer changes a litde while the internal force of the structure member above the conversion layer increase much.Under horizontal load,the deformation curve on the structure above conversion layer is shearing deformation mainly and the the deformation curve on the structure below the conversion layer is bending deformation mainly.The Conversion layer is the turning point between above and below deformation Curves.With no conversion layer,the max.Value appears on the low part of the structure.The top displacement increases with raising height of the conversion layer.The conversion layer is the place with small displacement between layers.Therefore,if the design is reasonable,the arched conversion layer Can have a perfect seismic performance.
Chen Jin, Wang Shiyong, Sun Liang. Finite Element Analysis Aboutstress Distribution of One - span Transfer Beam Supported on R. C. Fram e [ J ]. Building Science Research of Sichuan, 2004 (1): 35 - 37.
Tang Xingrong, Jiang Yongsheng, Ding Dajun. Experim ental study on Transfer Story Structure with Prestressed Concrete Truss [J ]. China Civil Engineer Journal, 2001 (4): 32 -40.
[3] Han -Seon Lee, Dong -Woo Ko. Seismic response characteristics of high -rise RC wall buildings having different irregularities in lower stories[J]. Engineering Structures, 2007 (10): 1 -18.
Wang Pingshan, Gan Gang, Sun Bingnan, etc. Analysis Of Thick Plate Transition Layer for High Rise Building [J]. Journal of Zhejiang University (Natural Science), 1998 (5): 570 -576.
Liang Jiongfeng , Zhang Min. Analysis of Effect of Stiffness Ration of Arch Transfer Floor Structure on Frequent Earthquake Reaction[J]. Special Structures, 2007(2): 65 -69.
Liang Jiongfeng, Yang Zeping, Wang Jianbao, etc. The Effect of Stiffness Ration on Seismic Behavior of Arch Transfer Floor Structure [ J ]. Journal of Railway Engineering Society, 2008(7): 98 -102.
Liu Jingsong, Qiu Tao. Study on Seismic Performance of Structure Affected by Long-span Steel Transfer Trusses Located at a Different High Level [ J ]. Earthquake Resistant Engineering and Retrofitting, 2006 (2): 46 -50.
Wang Sen,Wei Lian. Study on Influence of the High Level of Transfer Floor on the Structural Behavior of High -rise Building[J]. Building Structure, 2002(8): 54 -58.
[11]梁炯丰.拱式转换层结构弹性性能研究[D ].南昌:华东 交通大学, 2007.
Liang Jiongfeng. Study on Elastic Properties of Arch Transfer Floor Structure [D ]. Nanchang: East China Jiaotong University, 2007.