Abstract:Research purposes: Prefabricated concrete technology has been widely used in underground structures because of its advantages of high production efficiency, easy connection, energy conservation and environmental protection. In view of the poor seismic performance of prefabricated member connections, this paper proposes a fabricated access structure with section steel plug-in connections, and discusses its joint seismic performance. Through the low cycle repeated test, the bearing capacity, energy dissipation capacity, stiffness, failure mode and other indicators of the steel connection joints are obtained and the seismic performance of the steel socket joints is evaluated. Research conclusions: (1) The test and analysis results show that the failure mode of the specimens is the flexural ductility failure of the side wall as a whole. (2) Compared with cast-in-place specimens, the peak load-bearing capacity, stiffness, ductility and energy consumption of fabricated specimens are basically similar to those of cast-in-place specimens. (3) On the premise that the peak bearing capacity is basically the same, the specimen with a length of 500 mm of section steel has good ductility and energy dissipation performance, and is relatively economical. It is recommended to be used as the preferred scheme for the connection structure of prefabricated access joints.
Yee A A. Structural and Economic Benefits of Precast/Prestressed Construction[J].PCI Journal,2001(4):14-19.
[2]
Yee A A. Social and Environmental Benefits of Precast Concrete Technology[J].PCI Journal,2001(3):14-19.
[3]
Fukayama K,Shinagawa K.Design-Construction of Circular Roof for Underground Reservoir Using Precast Concrete Beams[J].PCI Journal,1998(5):46-54.
[4]
杜修力,刘洪涛,路德春,等.装配整体式地铁车站侧墙底节点抗震性能研究[J].土木工程学报,2017(4):38-47.Du Xiuli, Liu Hongtao, Lu Dechun, etc.Study on Seismic Performance of Sidewall Joints in Assembled Monolithic Subway Station[J]. China Civil Engineering Journal,2017(4):38-47.
[5]
Chen Z Y, Chen W, Zhang W. Seismic Performance Evaluation of Multi-Story Subway Structure Based on Pushover Analysis[J]. Advances in Soil Dynamics and Foundation Engineering, ASCE .2014,240:444-454.
[6]
Chen Z Y, Chen W, Li Y Y, etc. Shaking Table Test of a Multi-Story Subway Station under Pulse-Like Ground Motions[J].Soil Dynamics and Earthquake Engineering,2016,82:111-122.
[7]
陈之毅,刘文博,陈炜.多层地铁车站结构性能试验研究[J].同济大学学报:自然科学版,2020(6):811-820.Chen Zhiyi,Liu Wenbo, Chen Wei. Performance Experiment of a Multistory Subway Station[J]. Journal of Tongji University:Natural Science,2020(6):811-820.
[8]
米鹏,谭平,张亚飞, 等.装配式容差剪力墙及其推复性能分析[J].土木工程学报,2021(5):46-55.Mi Peng, Tan Ping, Zhang Yafei, etc. Pushover Analysis of the Precast Tolerance Concrete Shear Wall[J].China Civil Engineering Journal,2021(5):46-55.
[9]
Park R. Evaluation of Ductility of Structures and Structural Assemblages form Laboratory Testing [J].Bulletin of the New Zealand National Society for Earthquake Engineering,1989(3):155-166.