圆柱形钢管混凝土柱三维的解析解

黄 辉

铁道工程学报 ›› 2009, Vol. 26 ›› Issue (9) : 36-41.

PDF(273 KB)
PDF(273 KB)
铁道工程学报 ›› 2009, Vol. 26 ›› Issue (9) : 36-41.
路网研究

圆柱形钢管混凝土柱三维的解析解

  • 黄 辉
作者信息 +

Three—Dimensional Analytic Solution to Concrete Filled Steel Column

  • HUANG Hui
Author information +
文章历史 +

摘要

研究目的:钢管混凝土作为主要的承重构件在大型建筑以及桥梁结构中广泛应用。对于钢管混凝土承载力,特别对在温度荷载作用下的承载力研究基本是建立在实验的基础上。本文应用弹性力学中的逆解法引入Airy应力函数,以得到圆柱形钢管混凝土柱在轴向压力和温度的共同作用下,钢管与混凝土的应力状态、钢管与混凝土之间的相互作用力以及内部温度的解析表达式。
研究结论:在外部温度和轴向压力荷载的共同作用下,圆形钢管混凝土同一平面内温度、径向和法向应力是半径的曲线函数,而且温度大小仅与钢管和混凝土的热传导系数及截面尺寸有关;径向和法向应力不是单纯的按钢管与混凝土的刚度分配,而是与二者的刚度以及热传导系数相关。

Abstract

Research purposes: As a main load—bearing component,concrete filled steel column has been widely used in large—sized buildings and bridge structures.The research on the bearing capacity of concrete filled steel column,especially under the temperature load is on the basis of the experiment.In this paper,the Airy stress functions introduced in inverse method of elastic theory are used to obtain the stress status of steel column and concrete, interaction force between steel column and concrete under the joints effects of axial pressure and temperature on the concrete filled steel column and obtain the analytic formulas for the internal temperature.
Research conclusions: Under the joints effects of axial pressure and temperature,the temperature,radial stress and normal stress in the same plain face of concrete filled steel column are of the curve function of the radius,and the polynomials of temperature is only affected by the thermal conductivity coefficient.The radial stress and normal stress are Not simply affected by the stiffness of steel and concrete,but both with the stiffness thermal conductivity coefficient.

关键词

钢管混凝土柱 / 应力 / 温度 / 解析解

Key words

concrete filled steel column / stress / temperature / analytic solution

引用本文

导出引用
黄 辉. 圆柱形钢管混凝土柱三维的解析解[J]. 铁道工程学报, 2009, 26(9): 36-41
HUANG Hui. Three—Dimensional Analytic Solution to Concrete Filled Steel Column[J]. Journal of Railway Engineering Society, 2009, 26(9): 36-41
中图分类号: TU528.73   

参考文献

[1] Stenphen P.Schneider.Axially Loaded Concrete—Filled Steel Tubes[J].Journal of Structural Engineering,1998 (10):1125~1138.
[2] Ahmed Elremaily,Atorod Azizinamini. Behavior and Strength of Circular concrete—Filled Tube columns[J]. Journal of Constructional Steel Research,2002(1 2):1 567— 1591.
[3]J.B.Mander,M.J.N.Priestley,R.Park..Theoretical Stress—Strain Model for Confined Concrete[J].Journal of Structural Engineering,1988(3):1804—1826.
[4] 陈洪涛,钟善桐.钢管混凝土中混凝土的三向本构关系 [J].哈尔滨建筑大学学报,2000(6):13一17.
[5] 李国强,贺军利,韩林海.钢管混凝土轴压构件抗火承载 力的计算[J].建筑结构,2001(1):60—62.
[6] 姜绍飞,李明,卞忠宝,等.高温后方钢管混凝土钢材和混凝土的本构关系[J].辽宁工程技术大学学报,2005 (5):677—679.
[7] 王海华,丁永军,于德湖,等.ANSYS在钢管混凝土温度 场分布研究中的作用[J].青岛建筑工程学院学报,2005 (2):39—42.
[8] 余志武,丁发兴,林松.高温后钢管高性能混凝土轴压短 柱力学性能研究[J].铁道学报,2003(4):71—79.
[9] 丁发兴,余志武.恒高温后圆钢管混凝土轴压短柱弹塑 性分析[J].建筑科学与工程学报,2006(1):34—37.
[10]蒋丽忠,丁发兴,余志武.钢管自密实混凝土轴压受力机 理试验研究[J]。中国铁道科学,2006(4):38—44.
[11]韩林海,杨有福,霍静思.钢管混凝土柱火灾后剩余承载 力的试验研究[J].工程理学,2001(6):100—109.
 

PDF(273 KB)

2707

Accesses

0

Citation

Detail

段落导航
相关文章

/