The Effect of Stiffness Ration on Seismic Behavior of Arch Transfer Floor Structure |
LIANG Jiong-feng,YANG Ze-ping,WANG Jian-bao,YI Ping-hua |
East China Institue of Technology, Fuzhou, Jiangxi 344000, China |
|
|
Abstract Research purposes; The analyses are made for the effect of the stiffness ration on seismic behavior of the prestressed arch transfer floor structure which is a new type of transfer story structure.
Research conclusions ; The equivalent stiffness ration has an important impact on the sudden changes of the absolute displacement and the displacement angel between floors in transfer floor. When the floor shear suddenly changes in transfer floor and the equivalent stiffness ration is far away from 1.0,earthquake action may be more acute to this structure. It is suitable for control of the equivalent stiffness ration by 0. 8 to 1.5.
|
Received: 15 December 2007
|
|
|
|
|
[1]JGJ 3—2002,高层建筑混凝土结构技术规程[S].
[2]黄勤勇,吕西林.转换层上、下刚度比对框支剪力墙结构 抗震性能的影响[J].结构工程师,2003(1 ):17-23.
[3]GB 50011 —2001,中华人民共和国国家标准[S].
[4]陈树华,韩玉来,何建.结构转换层上下层间侧移角比取 值探讨[J].低温建筑技术,2005(5) :74 - 75.
|
|
|
|