Research on the Static and Dynamic Load Tests for Prestressed Concrete Continuous BOX Girder Bridge |
JIANG Chuan-jin |
China Railway Sixth Group Co.Ltd,Beijing 100036,China |
|
|
Abstract Research purposes: Based on the observing the stress and deformation in the control section and typical position of continuous box girder bridge under different static loads,the actual stress distribution and deformation of the bridge are obtained and based on the testing the actual stress of the bridge,the actual load—beating capacity of the bridge can be assessed and determined for providing measured data for the acceptance check of completion works.
Research conclusions: Through the static and dynamic 10ad tests,the parameters about stress,deformation and frequency of the bridge are obtained.The tests results show the theoretical analysis and calculation method uses for the bridge are feasible,and with which the construction quality can be guaranteed and the rigidity and load bearing capacity of the bridge can meet the requirements of the design and relative standards.
|
Received: 23 March 2009
|
|
|
|
|
[1] JTGD 60-2004,公路桥涵设计通用规范[S].
[2] YC 4-4 /1982,大跨径混凝土桥梁试验方法[S].
[3] 吴文清,叶见曙.预应力混凝土连续箱梁桥的静载力学 实验[J].工程力学, 2001(A02): 191 -195.
[4] GB 50010-2002,混凝土结构设计规范[S].
[5] NielsenMP. Limit analysis and concrete plasticity (A) [M ]. Engle wood Cliffs, New Jersey 07632, Prentice 2 Hall Inc. 1984.
[6] 白海峰.大跨度预应力混凝土连续箱梁施工监测控制研 究[J].铁道工程学报, 2008(3): 38 -41.
|
|
|
|