Abstract Research purposes:The substation of the Qinhuangdao - Shenyang Passenger Dedicated Line is a substation with the single phase transformer wiring form and its outlet phase splitting only has the partition function. After expansion of the capacity of the transformer,the wiring form was changed into the VX junction,and the existing phase splitting can not meet the demand of running the double EMUS . In order to meet the technical demand of running the double EMUs,it is necessary to do the research on upgrading of the anchor articulated phase splitting of Sanhaiguan Substation for 11 span catenary of the Qinhuangdao - Shenyang Railway.
Research conclusions:To reduce the interference on the transportation and the work volume,it is recommended to increase insulation and substitute four insulation joints for some five span insulation joints to make the length of the zone without power longer than 220m for meeting the demand of running the double EMUs. The solution is also presented on upgrading of the outlet phase splitting of the single phase wiring form transformer in order to enhance the operation reliablity.
|
Received: 12 April 2012
|
|
|
|
|
[1] TG/03—2009,铁路客运专线技术管理办法[S].
TG /03—2009, High - speed Passenger Railway Technology Management Approach[S].
[2] TB 10621—2009,高速铁路设计规范[S].
TB 10621—2009,Code for Design of High Speed Railway[S].
[3] 朱学辉,陈玉泉,张虎年,等. 关节式电分相线索烧损原因及防范措施[J].电气化铁道,2007(4) :32-35.
Zhu Xuehui,Chen Yuquan,Zhang Hunian,etc.Causes of Burn - out of Articulated Phase Breaker Cable and Its Prevention Measures [J].Electric Railway,2007 (4) :32-35.
[4] 邵立,刘永红.适应双列重联动车组接触网电分相改造的研究[J]. 铁道标准设计,2008(2) :95-97.
Shao li,Liuyonghong. Research on Transformation of Electricity Split Phase in Overhead Contact System Adapting to Double Locomotive EMUs[J].Railway Standard Design,2008(2) : 95-97.
[5] 刘明光,路延安,魏宏伟,等.关节式电分相过电压试验研究[J]. 电气化铁道,2007(4) :1-17.
Liu Mingguang,Lu Yanan,Wei Hongwei,etc. Study on Articulated Neutral Section Over - voltage Test[J]. Electric Railway,2007(4) : 1-17.
[6] 孙书贝. 适合于动车组的空气绝缘电分相探讨[J]. 电气化铁道,2007(5) : 38-40.
Sun Shubei. Apply to Emu Air Insulated Electric Points Phase[J]. Electric Railway,2007(5) : 38-40.
[7] 周凡. 大西客运专线接触网电分相的选择与应用[J]. 铁道工程学报,2010(6) :79-82.
Zhou Fan. Choice and Application of Electric Section Insulator of Overhead Contact Wire for Datong - Xi'an Passenger Dedicated Line [J]. Journal of Railway Engineering Society,2010(6) : 79-82.
[8] 耿敬春. 基于 CTCS -3 级列控系统动车组列车自动过分相运行检算[J]. 铁道工程学报,2010(10) :93-98.
Geng Jingchun. Checking Calculation of Auto - passing Phase Splitting by CTCS - 3 based EMU[J]. Journal of Railway Engineering Society,2010(10) : 93-98.
[9] TB/T 2809—2005. 电气化铁道用铜及铜合金接触线[S].
TB /T 2809—2005,Copper and Copper - Alloy Contact Wires for Electric Railway[S].
[10] TB/T 3111—2005. 电气化铁道用铜及铜合金绞线[S].
TB /T 3111—2005,Stranded Copper and Copper - Alloy Conductors for Electric Railway[S].
|
|
|
|