Test and Analysis of Vibration Induced by Elevated Railway and Anti -vibration Measure

ZHANG Liang - tao

Journal of Railway Engineering Society ›› 2012, Vol. 29 ›› Issue (6) : 118-125.

PDF(854 KB)
PDF(854 KB)
Journal of Railway Engineering Society ›› 2012, Vol. 29 ›› Issue (6) : 118-125.

Test and Analysis of Vibration Induced by Elevated Railway and Anti -vibration Measure

  • ZHANG Liang - tao
Author information +
History +

Abstract

Research purposes: The planned Shanghai - Nantong Railway will pass through the Shanghai Waigaoqiao Free Trade Zone on viaduct and it will be about 250 m away from a chip processing plant. In order to ensure the normal production of the chip processing factory,it is necessary to test and analyze the vibration induced by the elevated railway and present the anti - vibration measures according to the test results.
Research conclusions:The vibration value of the place around the chip processing factory has exceeded the allowable vibration velocity for the foundation of the chip processing workshop because of the vibration induced by the container truck on the peripheral road. The similar vibration tests and monitoring for the existing Shanghai - Hangzhou Railway showed the vibration value of the ground 250 m away from the track was equivalent to the that of the chip processing factory when the passenger train met with the freight train and it exceeded the allowable vibration velocity. On consideration of that the building was built in the place about 500 m away from the railway,the study mainly demonstrated how to reduce the vibration level of the place 250 m far away from the railway to being equivalent to that of the place 500 m far away from railway. The study showed the anti - vibration measures were feasible.

Key words

railway / viaduct / vibration / test / measures

Cite this article

Download Citations
ZHANG Liang - tao. Test and Analysis of Vibration Induced by Elevated Railway and Anti -vibration Measure[J]. Journal of Railway Engineering Society, 2012, 29(6): 118-125

References

[1] 张弥,夏禾,冯爱军. 轻轨列车和高架桥梁系统的动力响应分析[J]. 北方交通大学学报,1994(1):1 -8.
Zhang Mi,Xia He,Feng Aijun. Dynamic Responses of Light - Rail Train and Viaduct Bridge System [J]. Journal of Northern JiaoTong University,1994(1):1 -8.
[2] 张昕,蒋通. 考虑轨道不平顺的车 - 桥动力分析[J]. 力学季刊,2003(1):19 -26.
Zhang Xin,Jiang Tong. Dynamic Analysis of Train - bridge System Considering Rail Irregularity [J]. Chinese Quarterly of Mechanics,2003(1):19 - 26.
[3] Shen - Haw Ju. Finite Element Analysis of Building Vibrations Induced by High – speed Train [J].Environmental Vibration , Chen&Takemiya ( eds. ),Hangzhou,China,2003:252 - 263.
[4] Takemiya H and Fujiwara A. Wave Propagation - impediment in a Stratum and Wave Impeding Block (WIB) Measured for SSI Response Reduction[J]. Soil Dynamics and Earthquake Engineering,1994(1):49 -61.
[5] Terumi TOUHEI. Impulsive Response of an Elastic Layered Medium in the Anti - Plane Wave Field Based on a Thin - Layered Element and Discrete Wave Number Method[J]. Structural Eng. /Earthquake Eng. ,JSCE,1993(22):119 - 128.
[6] 高广运,杨先健,王贻荪,等. 排桩隔振的理论与应用[J]. 建筑结构学报,1997(4):58 -68.
Gao Guangyun,Yang Xianjian,Wang Yisun,etc.Theory and Application of Vibration Isolation by Piles inRows[J]. Journal of Building Structures,1997(4):58 - 68.
[7] 高广运,李伟. 二维地基波阻板隔振分析[J]. 地震工程与工程振动,2005(2):130 -135.
Gao Guangyun,Li Wei. 2 - D Analysis of Ground Vibration Isolation Using Wave Impeding Block[J]. Earthquake Engineering and Engineering Vibration ,2005(2):130 - 135.
[8] 肖世伟,雷长顺,郭超,等. 高速铁路空沟隔振数值分析[J]. 铁道工程学报,2011(8):23 -29.
Xiao Shiwei, Lei Changshun, Guo Chao, etc. Numerical Analysis of Vibration Reduction of Open Trench for High - speed Railway [J]. Journal of Railway Engineering Society,2011(8):23 - 29.
[9] 罗锟,雷晓燕,刘庆杰,等. 地屏障在铁路环境振动治理工程中的应用研究[J]. 铁道工程学报,2009(1):1 -6.
Luo Kun,Lei Xiaoyan,Liu Qingjie,etc. Research on the Application of Ground Barrier in Reducing the Vibration Along High - speed Railway[J]. Journal of Railway Engineering Society,2009(1):1 -6.
 