Study on Distribution Law AND Observation of Ground Temperature in Spring along Xi’an Subway |
REN Jian - xi1,LIU Jia - hui1,GAO Hu - yan2,YANG Zhi - guo3,ZHOU Xiao - yan4,GAO Ting - ting1 |
1. Xi'an University of Science and Technology,Xi'an,Shanxi 710054,China; 2. Xi'an City Metro Co. Ltd,Xi'an,Shanxi 710016,China; 3. China Railway First Survey and Design Institute Group Co. Ltd,Xi'an,Shanxi 710043,China; 4. Shanxi Institute of Engineering Prospecting,Xi'an,Shanxi 710068,China |
|
|
Abstract Research purposes: Xi'an is the first city to build the subway in loess in China,with a little information on the distribution law of the ground temperature in the subway buried depth range. The study was done on the long - term distribution law of ground temperature of the four typical geomorphic units along the Xi'an subway to obtain the constant temperature strata position of the different geomorphic units and the distribution laws of the ground temperature in Spring for providing the reference to the air - conditioning design for the subway station and sectional tunnel.
Research conclusions: The analysis and study were done on the observation information of nine observation points along the Xi'an subway. The study results showed that the constant temperature strata position of the Zaohe first terrace was in the 10 meters under the ground surface with the temperature of 15 ℃,the constant temperature strata position of the loess ridge was in the 9 m under the ground surface with the temperature of 17 ~ 18 ℃,the constant temperature strata position of Weihe first terrace was in 10 meters under the ground surface with the temperature of 15. 5 ℃,and the constant temperature strata position of Weihe third terrace was in 9 meters under the ground surface with the temperature of the 16. 5 ℃.
|
Received: 14 October 2011
|
|
|
|
|
[1] 张琛,刘胡州,沈凯,等. 地铁公共区空调系统风管流量调节特性测试分析[J]. 建筑热能通风空调, 2010( 4) : 18 -20.
Zhang Chen,Liu Huzhou,Shen Kai,etc. Analysis Based on Testing of the Duct Flow Characteristics of Air -conditioning System in Public Areas of Subway[J].Building Energy & Environment, 2010( 4) : 18 - 20.
[2] 张琛,沈凯,吴喜平,等. 地铁公共区空调系统风管流量调节特性测试分析[J]. 洁净与空调技术,2010 ( 1) : 13 -15.
Zhang Chen,Shen Kai,WU Xiping, etc. Analysis Based on Testing of the Duct Flow Characteristics of Air -conditioning System in Public Areas of Subway [J].Contamination Control & Air - Conditioning Technology, 2010( 1) : 13 - 15.
[3] 樊玲,冯炼. 利用“相对热流指标”对地铁系统设计温度的探讨[J]. 城市轨道交通研究, 2002( 1) : 50 - 52.
Fan Ling,Feng Lian. Design Temperature of Metro System By Using Relative Warmth Index[J]. Urban Mass Transit, 2002( 1) : 50 - 52.
[4] 章熙民,任泽霈,梅飞鸣. 传热学[M]. 北京: 中国建筑工业出版社, 2001.
Zhang Ximin,Ren Zepei,Mei Feiming. Heat Transfer M]. Beijing: China Architecture & Buliding Press,2001.
[5] 辛伟宁,赵蕾,朱常琳. 地铁站内空调控制温度及系统运行模式[J]. 都市快轨交通, 2009( 4) : 57 - 60.
Xin Weining,Zhao Lei,Zhu Changlin. Operational Temperatures and Modes of Air - conditioning System in Subway Station[J]. Urban Rapid Rail Transit,2009 ( 4) : 57 - 60.
[6] 刘争平. 多年冻土地区地温测试关键技术研究[J]. 铁道工程学报, 2009( 2) : 35 - 39.
Liu Zhengping. Study on the Technology for Ground Temperature Test in Permafrost Region[J]. Journal of Railway Engineering Society,2009( 2) : 35 - 39.
[7] 肖琳,李晓昭,赵晓豹,等. 含水量与孔隙率对土体热导率影响的室内实验研究[J]. 解放军理工大学学报,2008( 3) : 242 - 247.
Xiao Lin, Li Xiaozhao, Zhao Xiaobao, etc. The Laboratory Study on the Influences of Moisture Content and Porosity on Thermal Conductivity of Soils [J].Journal of PLA University of Science and Technology( Natural Science Edition) , 2008( 3) : 242 - 247.
|
|
|
|