Performance-based Analysis of the Fire Prevention Design for the Large-scale Subway Station |
ZENG Guo-bao |
TheThird Survey and Design InstituteGroup Corporation, Tianjin 300251, China |
|
|
Abstract Research purposes:This paper analyzes the fire prevention design for the large scale subway station with many exits, large concourse area, long evacuation distance, long underground passage andmany shops, for the purpose ofproviding reference to design of the interchange station and other large scale subway station.
Research conclusions:The exits and entrances should be in the places where there is enough free room for the passengers to evacuate. The stairs should be closed consideredwhen the platform is far from the ground. Smoke emission and other automatic fire prevention facilities should be equipped in large concourse area, and the fire prevention facility should be also designed for the shopping area.
|
Received: 20 October 2008
|
|
|
|
|
[1] GB 50157)2003,地铁设计规范[S].
[2] GB50016)2006,建筑设计防火规范[S].
[3] DGJ08)109)2004,城市轨道交通设计规范[S].
[4] 曾国保,刘大治,张利民,等.上海轨道交通9号线一期 工程施工图设计[R].天津:铁道第三勘察设计院集团 有限公司, 2007.
[5] 国家消防工程技术研究中心.天津轨道交通线换乘站安 全设计评估报告[R] .天津:国家消防工程技术培训 中心, 2008.
|
|
|
|