Abstract Research purposes:In consideration of CPónetwork and accuracy required for observed values, the simulated calculation on necessary positional accuracy ofCPónetwork and improved CPIII net form was performed. And through theoretical analysis of error, the discussions were made on the reasonable positioning precision ofCPó points in two circumstances and the reasonable permissible error of coordinate difference in the direction ofxandy.
Research conclusions:By calculating the positional accuracy required forCPócontrolnetwork based on the parameter adjustmentof side-angle measurement network, the result shows the improved CPIII net form is better in integration intensity, but it isworse in positional accuracy, especially in lateral accuracy, compared with the CPónetwork. For the CPónetwork, the repeatablemeasurement accuracy should be less than?1. 5 mm and the coordinate difference tolerance should be less than?3. 0 mm in the direction coordinate ofxandy. For the improved CPónet form, the corresponding repeatablemeasurement accuracy and permissible difference should be less than?2.0 mm and?4.0 mm respectively.
|
Received: 08 October 2008
|
|
|
|
|
[1] 铁建设[2006]189号,客运专线无碴轨道铁路工程测量 暂行规定[S].
[2] 武汉大学测绘学院-测量平差学科组.误差理论与测量 平差基础[M].武汉:武汉大学出版社, 2003.