DIAGNOSIS OF LARGE-SPAN BRIDGE'S DAMAGE |
YUAN Ming1, HE Guo-jing2 |
1Chinese Railway General Engineering Corporation, 2Civil Engineering Institute of Central South University |
|
|
Abstract A simple FEM of Ting Kau cable-stayed bridge is built, its dynamic characterizes arc analyzed and many simulated damage cases in the FEM arc investigated by using a structural damage detection method, CMSE, proposed by author. Results indicate that the dynamic characterizes of the simple FEM arc similar to those of Ting Kau cable-stayed bridge and CMSE is the same with flexible structures with low and intense frequencies such as long-span cable-stayed bridge and has satisfying precision in damage detection only using a few low modes.
|
Received: 21 August 2003
|
|
|
|
|
[1]史治宇,吕令毅.由模态应变能法诊断结构破损的实验研究[J].东南大学学报1999.3.
[2]史治宇,张令弥,吕令毅.基于模态应变能诊断结构破损的修正方法[J].东南大学学报,2000.5.
[3]袁明,贺国京.基于模态应变能的结构损伤检测方法研究铁道学报[J]. 2002.2.
[4]Research reports of Hong Kong Polytechnic University, Finite Element Modelling and Modal Sensitivity Analysis of the Ting Kau Cable-Stayed Bridge [M].
|
|
|
|