Research on Lightning Performance of Traction Network for High - speed Railway Based on Striking Distance Method |
SUN Zhang-lin,FAN Chun-lei |
China Railway Electrification Survey Design & Research Institute Co.Ltd,Tianjin 300250,China |
|
|
Abstract Research purposes:Recently more lightning failures happened on the traction network for high - speed railway,which endangered the security of railway operations and personal. By the model of the striking distance method,the paper quantitatively calculates the total number of trip - out under the typical layout of the viaduct traction network for high - speed railway.
Research conclusions:The results show that the total number of trip - out will be high in the typical layout of traction network.which will be 25. 37878 times per 100 kilometer per year. Among them,there are 25.1508 times per 100 kilometer per year caused by striking on positive feeder,account for 99.1 percent.Finally,the paper promotes a improved optimization schemes of the typical layout of traction network ,Take first scheme as an example,the total number of trip - out have only 13.2579 times per 100 kilometer per year. Compared with the typical layout of traction network,the total number of trip - out decreased by 52.2 percent,so which have the important reference value for lightning protection in the future.
|
Received: 30 May 2012
|
|
|
|
|
[1] 樊春雷,郭小霞,李汉卿. 高速铁路暂态模型搭建与仿真分析[J]. 电气化铁道,2011(5) :9-11.
Fan Chunlei, Guo Xiaoxia,Li Hanqing. Simulation Analysis and Transient Modeling for High - speed Railway[J]. Electric Railway,2011(5) : 9-11.
[2] 王晓彤,施围,等. 改进电气几何模型计算输电线路绕击率[J]. 高电压技术,1998(1) :85-87.
Wang Xiaotong,Shi wei,etc. Calculation of Shielding Failure on Transmission Line by Improved EGM[J]. High Voltage Engineering,1998(1) : 85-87.
[3] 李晓岚. 击距系数及基于电气几何模型的输电线路绕击跳闸率计算的研究[D]. 武汉: 华中科技大学,2005.
Li Xiaolan. Study on Striking Distance Factor and Calculation of Shielding Failure Flashover Rate for Transmission Line Based on Electric Geometry Method [D].Wuhan: Huazhong University of Science and Technology,2005.
[4] 李晓岚,尹小根,等. 基于改进电气几何模型的绕击跳闸率的计算[J]. 高电压技术,2006(3) :42-44.
Li Xiaolan,Yin Xiaogen,etc. Calculation of Shielding Failure Flashover Rate Based on Revised EGM [J]. High Voltage Engineering,2006(3) : 42-44.
[5] 于增. 接触网防雷技术研究[J]. 铁道工程学报,2002 (1) :89-94.
Yu Zeng. Study on Lightning Protection of Catenary [J]. Journal of Railway Engineering Society,2002(1) : 89-94.
[6] 范海江,罗健. 铁路客运专线接触网防雷研究[J]. 铁道工程学报,2008(8) :80-83.
Fan Haijiang,Luo Jian. Research on the Lightning Protection of OCS in Passenger Dedicated Lines[J]. Journal of Railway Engineering Society,2008(8) : 80-83.
[7] 赵智大. 高电压技术[M].北京: 中国电力出版社,2006.
Zhao Zhida. High Voltage Technology[M].Beijing: China Electric Power Press,2006.
|
|
|
|